how does one work Nitrous oxide sedation? What components of nitrous oxide devices is there? And how do I close it Nitrous oxidemasken hose on?
We explain all these questions and more to yours Nitrous oxide-Mixer and Nitrous oxide-Hose system in our FAQ videos.

FAQ Videos - The most frequently asked questions about the nitrous oxide device

Baldus Touch - nitrous oxide sedation process

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

The stand-by button is located to the right of the screen. To switch the device to stand-by mode, please press and hold the stand-by button for 3 seconds. When you turn on the device, the device performs a self-test. In our main menu you have two different options. Once the Sedation Start anonymously or with a patient ID. We start by entering a patient ID. A menu with letters and numbers opens; thus a patient can be created with name or patient number. After you click Enter, the Sedation directly with 5l/min total flow and 0% N2O (=100% O2). At an “Anonymous Sedation", without depositing a patient ID it will be Sedationsscreen displayed. the Sedation the Sedation starts immediately with 5l/min and 0% N2O (=100% O2). On the screen below you will see the treatment time as well as the date and time. You can see it at the top right Total flow, that is, how many liters gas mixture the device emits per minute. Of the Total flow is approximately determined based on the size of the patient. Then you start with the Sedation. throughout Sedation are the vital signs of the patient using our pulse oximeters to monitor. During the Sedation please always make sure that the breathing bag with enough gas mixture is filled. In the example video you can see that they have a maximum of 70% Nitrous oxide can be administered to the patient. This ensures that the patient is always supplied with enough oxygen.
GOOD TO KNOW: With the help of the mixer, medical oxygen becomes medical oxygen in percentage terms Nitrous oxide mixed in. The patient remains conscious but becomes more relaxed and less anxious about the treatment. According to various specialist books and studies, the Nitrous oxide sedation up to a maximum of 70% Nitrous oxide to a minimum Sedation with the aim of anxiolysis (Anxiety release) in the patient. It isn't anesthesia, the patient is awake, breathing independently and is able to react to external stimuli. In some patients, the sedative effect of 50% Nitrous oxide not sufficient, for this reason there is next to the device Baldus® Touch 50, which maximum 50% Nitrous oxide can also administer the devices Baldus® Touch 60 and 70, which at maximum 60% and 70% Nitrous oxide are limited. In this way, the trained user can decide for himself which maximum nitrous oxide dose he wants to work. the nitrous oxide concentration is individually tailored to the patient. The Baldus ® Touch 50, 60 and 70 variant is a built-in variant which can be used e.g. B. can be installed in the Baldus® All-in-One-Cart or in a plasterboard wall.

With the help of O2 Flush function, you always have the option of administering 50 to 60 liters of oxygen to the patient.

After the treatment, you can use the "Sedation discharge" the Sedation break up. The patient immediately gets 100% oxygen at the total flow you have issued. This elimination phase lasts 5 minutes, which you screen can also track.

How do I properly bleed the Baldus Touch?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

In the video we show you how to bleed the Baldus Touch. First one anonymous sedation started. Then we give the maximum N2O concentration at any one Total flow a. Now the blue first nitrous oxide cylinder turned clockwise. We can on that Pressure reducer watch how it slowly falls now. The "Error message" now appears on the screen N2O Check gas supply, as is acknowledged.

Next, the oxygen cylinder is turned off clockwise. Also here we can observe how the pressure gauge falls and on the screen the "error message" O2 Check gas supply appears, which is also acknowledged. The entire system is now bled. Now you can either put the device in the Standby mode or press and hold the power button for about 7 seconds until the red light turns off and the system shuts down.

How does sedation work with the Baldus Analog?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

With the right rotary control you can adjust the flow. Using the left rotary control Nitrous oxide added. Up to a maximum concentration of 70%. The Baldus Analog is also available as Baldus Analog 50 and Baldus Analog 60 which are limited to a maximum of 50% or 60%.

Please pay attention to the knobs, these EASY to move and not to overdrive. With the O2 Flush function on Baldus Analog (see video) you can immediately administer 50 to 60 liters of pure oxygen to the patient.

How do I properly bleed the Baldus Analog?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

With the right rotary control you can adjust the flow. Using the left rotary control Nitrous oxide added. Up to a maximum concentration of 70%. The Baldus Analog is also available as Baldus Analog 50 and Baldus Analog 60 which are limited to a maximum of 50% or 60%.

Please pay attention to the knobs, these EASY to move and not to overdrive. With the O2 Flush function on Baldus Analog (see video) you can immediately administer 50 to 60 liters of pure oxygen to the patient.

How do I connect the vacuum control block?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

The suction and our vacuum control block: You can connect our control block to both the small and the large chair suction. If necessary, our adapter can also be used in both cases.

In any case, he should Vacuum Control Block can be adjusted using the rotary control so that the bead "flies" in the middle. You have now optimally adjusted the suction. This is also illustrated in the video:

How do I assemble the scavenger system?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

This video is about the hose system - ours Baldu's scavenger system and how this is put together. You start with that breathing bag. This will be at the bottom of the BAG-T fastened.  Now the corrugated hose is fixed with the help of the connectors with the double hose tied together.

Then the free end of the corrugated hose is connected to the front outlet of the BAG-T plugged. Now the suction hose is assembled. The package contains a longer and a shorter hose. Now he has to Vacuum Control Block placed in the right direction between the 2 hoses. The shorter hose is placed on the designation “VAC” (pronounced suction). The longer hose is attached to the part of the vacuum control block where "MASK" stands.

Now the free end of the longer hose is on the double hose attached. Last but not least, they can hanger onto the vacuum hose so that you can hang it anywhere you like. Then the suction hose can be connected to the chair suction.

In the video, our technician shows how easy it is to attach the baldus Scavenger system is.

The Baldus Scavenger System / Purpose

That Baldus® doublemaskensystem was developed to the indoor air pollution through Nitrous oxide reduce and protect staff. The oxygen isNitrous oxide-Mixture in the Inner mask of the patient and the patient breathes that gas mixture a. When you exhale, one opens membrane and the gas is about the outer maske and the vacuum hose derived.

Because the patient's breathing is decoupled from the suction, he gets more comfortable air. Thanks to the perfect fit and the soft material, the maske to every face shape. the outer maske has the function of a vacuum bell, that is, it sucks the micro-leakage z. B. caused by a mustache, efficiently.

Tips and tricks nitrous oxide pressure reducer

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

the Pressure reducer be at the annual maintenance checked and all seals exchanged. We have different thread sizes to accommodate these can never be interchanged. In the video on the left you can see the N2O Pressure reducer and on the right O2 Pressure reducer. In the N2O Seal it is important to ensure this before changing the bottle let it rest for at least 10 minutes because it expands a lot.

How do I change the gas bottle?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

This video is about the correct one Gas bottle change. For this you need the oxygen and oxygen shown in the video nitrous oxide cylindern. For transportation are the gas bottlen fitted with protective caps. The first step is to unscrew the caps. the Pressure reducer the gas cylinders are then turned on to the connection provided. Of the Nitrous oxide-Pressure reducer with the small thread, the oxygenPressure reducer with the big thread. It is important to only screw on both pressure reducers hand-tight. Now both come gas bottlen in the car. On the right side oxygen, on the left side that Nitrous oxide. Both bottles are secured with the belt against tipping over. Then the pressure hoses with the gas bottlen connected. Be sure to pay attention to the color coding. the blue one pressure hose comes to the blue nitrous oxide cylinder, the White pressure hose to the white oxygen bottle. To shoot, both wrongs are turned counterclockwise.

When is the gas bottle empty?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

This video is about the filling level of the gas bottlen and when the time comes, new ones to order gas cylinders. A full oxygen cylinder is 200 bar, Am Pressure reducer you can always see the level of the gas bottle read off. a full nitrous oxide cylinder has 50 bars. Nitrous oxide is a LPG. Therefore, the level of the nitrous oxide cylinder Not on Pressure reducer read off.

A full bottle gives you approximately 600 minutes of treatment time. Once the ad on the Pressure reducer has reached the red mark, you still have approx. 100 minutes of treatment time. Now it's time to get a new one gas bottle take care of. We always recommend at least one nitrous oxide cylinder to keep in reserve.  

How do I put the double nasal mask together?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

This video is about the filling level of the gas bottlen and when the time comes, new ones to order gas cylinders. A full oxygen cylinder is 200 bar, Am Pressure reducer you can always see the level of the gas bottle read off. a full nitrous oxide cylinder has 50 bars. Nitrous oxide is a LPG. Therefore, the level of the nitrous oxide cylinder Not on Pressure reducer read off.

A full bottle gives you approximately 600 minutes of treatment time. Once the ad on the Pressure reducer has reached the red mark, you still have approx. 100 minutes of treatment time. Now it's time to get a new one gas bottle take care of. We always recommend at least one nitrous oxide cylinder to keep in reserve.  

How do I send the Baldus in for maintenance?

YouTube

By loading the video, you accept YouTube's privacy policy.
Learn more

load video

Our maintenancepackage: This video is about submitting your Baldus Analog to the annual maintenance in our transport system. For our customers who Baldus Analog to the prescribed annual maintenance ship, we have developed a transport system with which a safe shipping of your expensive and high-precision Nitrous oxidemixer and the accessories guarantee.

In the maintenance box for the analog mixer have next to the device and the Pressure reducern also the hose system that masken, the Vacuum Control Block, the breathing bag and the pressure hoses have enough space. The prefabricated recesses ensure flawless and secure shipping. Please send us yours medical device book with a so that we die maintenance can document. The delivery note is also very important. Please enter here which components and how many you have packed.

With our well thought out maintenance box you don't have to worry about damage in transit. In the following video you can see how easy it is Baldus Analog to the maintenance can send.

Shopping Cart
Scroll to Top